v7.0.72 Firmware Release
Upgrade your device to this release now with the following command template:
$LOAD,astraupgrades.com,81,/fw/<MODEL>/<CLIENT>/<VARIANT>/7.0.72,ATFW.bin
<MODEL> = Your device’s model number (e.g. AT202)
<CLIENT> = Your client trigraph (e.g. AST)
<VARIANT> = Your custom variant number (e.g. VAR03)
Feature Release Notes:
$RSCD (Reporting schedule) Implemented
Use $RSCD to configure your device to report at up-to 6 fixed times of the day at minute resolution instead of at a $STIM interval. Example: $RSCD,09:00,15:00,21:00,23:58
$TMZN (Time zone) Implemented
Use $TMZN to configure your device’s on-board time zone. This setting will take effect when evaluating the device’s $RSCD (Report Schedule) or $IMOS (Immobiliser Schedule)
$TEST “ND” GPS status added to indicate hardware fault
Integration Release Notes:
Heinzmann CargoPower Controller CANBus integration
Firmware option for CPX Scooter 1-wire seat unlock sequence
Performance Improvement Release Notes:
CFUN0->1 Socket open error management
$RATC 2G Default restored for BG600L-M3 devices
Quectel LTE modules improved socket state handling via QISTATE
Quectel BG600L-M3 DFOTA disabled
Bugfix Release Notes:
Quectel AT+QENG response parsing when RAT != GSM